PDU
-
36 PORTS P14&8 PORTS C19 BASIC RACK PDU
Bayanan Bayani na PDU:
1. Input Voltage: uku lokaci 346 ~ 480V
2. Shigarwa Yanzu: 2*(3*125A)
3. Fitar wutar lantarki: guda-lokaci 200 ~ 277V
4. Kanti: 36 tashoshin jiragen ruwa na 4-pin PA45 (P14) Sockets 8 tashar jiragen ruwa na C19 Sockets
5. Biyu tashar jiragen ruwa Haɗaɗɗen 125A babban mai watsewa (UTS150HT FTU 125A 3P UL)
6. Kowane tashar jiragen ruwa yana da 1P 277V 20A UL489 na'ura mai aiki da karfin ruwa Magnetic circuit breake.
-
40 PORTS C19 BASIC RACK PDU
Bayanan Bayani na PDU:
1. Input Voltage: uku lokaci 346 ~ 480V
2. Shigarwa Yanzu: 3*250A
3. Fitar wutar lantarki: guda-lokaci 200 ~ 277V
4. Outlet: 40 tashoshin jiragen ruwa na C19 Sockets da aka tsara a cikin sassa uku
5. Kowane tashar jiragen ruwa yana da 1P 20A mai katsewa
-
18 PORTS C19&2 PORTS C13 BASIC PDU
Bayanan Bayani na PDU:
1. Input Voltage: uku lokaci 346 ~ 415V
2. Input Current: 2 sets na 3*60A, daya daga kowane bangare na PDU
3. Fitar wutar lantarki: guda-lokaci 200 ~ 240V
4. Fitarwa: 18 C19 Sockets masu kulle kai (20A Max) 2 C13 Sockets masu kulle kai (15A Max)
5. 6 inji mai kwakwalwa 1P 60A UL489 breakers, kowanne yana kare kwasfa 3
6. C13 tashar jiragen ruwa guda biyu don masu sauya hanyar sadarwa
7. Foda shafi: Pantone Black
-
18 PORTS C19 PDU
Bayanan Bayani na PDU:
1. Input ƙarfin lantarki: 3-phase 346-415VAC
2. Shigarwa na yanzu: 3 x125A
3. Wutar lantarki mai fitarwa: guda-lokaci 200 ~ 240 VAC
4. Outlet: 18 tashoshin jiragen ruwa na C19 soket tare da kulle fasalin da aka tsara a cikin sassa uku
5. 3P 125A UL489 Hydraulic Magnetic main circuit breaker
6. Kowane tashar jiragen ruwa yana da 1P 20A UL489 Hydraulic Magnetic circuit breaker
-
18 PORTS C13 PDU
Bayanin PDU:
1. Input Voltage: uku lokaci 346 ~ 415V
2. Shigarwa Yanzu: 3*100A
3. Fitar wutar lantarki: guda-lokaci 200 ~ 240V
4. Outlet: 18 tashoshin jiragen ruwa na C13 Sockets da aka tsara a cikin sassa uku
5. 9×32A 1P breakers,kowane Breaker iko 2 kwasfa
6. Ɗaya daga cikin tashar jiragen ruwa C13 don cibiyar sadarwa, tare da 1P / 2A breake
-
6 PORTS C19 SMART PDU
Bayanan Bayani na PDU
1. Input Voltage: uku lokaci 346 ~ 400V
2. Shigarwa Yanzu: 3*32A
3. Wutar lantarki mai fitarwa: guda-lokaci 200 ~ 230V
4. Outlet: 6 tashar jiragen ruwa C19 kwasfa, shirya a cikin sassa uku
5. Kowane tashar jiragen ruwa yana da 1P 20A UL489 na'urar kewayawa
6. Smart mita module tare da onboard LCD nuni da kuma menu iko
7. Ethernet / RS485 dubawa, goyon bayan HTTP / SNMP / SSH2 / MODBUS
8. Kulawa mai nisa da sarrafa ON / KASHE kowane tashar jiragen ruwa
9. Shigar da saka idanu mai nisa da kowane tashar tashar jiragen ruwa, ƙarfin lantarki, wutar lantarki, factor factor, KWH
10. Rack-mounted shigarwa, amfani a cikin bayanai cibiyar
-
18 Tashar jiragen ruwa P34 Smart PDU
Bayanan Bayani na PDU:
1. Input ƙarfin lantarki: 3-phase 346-480 VAC
2. Shigarwa na yanzu: 3 x 150A
3. Wutar lantarki na fitarwa: 3-phase 346-480 VAC ko guda-lokaci 200 ~ 277 VAC
4. Outlet: 18 tashoshin jiragen ruwa na 6-pin PA45 Sockets da aka tsara a cikin sassa uku
5. Kowane tashar jiragen ruwa yana da 3P 20A Circuit Breaker (3P 16A/25A na zaɓi)
6. PDU ya dace don 3-phase T21 da S21 guda-lokaci
7. Kulawa mai nisa da sarrafa ON / KASHE kowane tashar jiragen ruwa
8. Mai saka idanu mai nisa na shigar da halin yanzu, ƙarfin lantarki, wutar lantarki, factor factor, KWH
9. Onboard LCD nuni tare da sarrafa menu
10. Ethernet / RS485 dubawa, goyon bayan HTTP / SNMP / SSH2 / MODBUS
11. Ciki fan tare da LED nuna alama
-
3 Tashar jiragen ruwa P34 Smart PDU
Bayanan Bayani na PDU:
1. Input ƙarfin lantarki: 3-phase 346-480 VAC
2. Shigarwa na yanzu: 3 x 30A
3. Kebul na shigarwa: toshe L22-30P tare da UL ST 10AWG 5/C 6FT na USB
4. Wutar lantarki na fitarwa: 3-phase 346-480 VAC ko guda-lokaci 200 ~ 277 VAC
5. Kanti: 3 tashoshi na 6-pin PA45 (P34), 3-phase/single-single jituwa
6. Haɗe-haɗe na 3P 30A babban mai katsewa
7. Kulawa mai nisa da sarrafa ON / KASHE kowane tashar jiragen ruwa
8. Mai saka idanu mai nisa & kowane tashar tashar jiragen ruwa, ƙarfin lantarki, wutar lantarki, PF, KWH
9. Smart Meter tare da kewayon Ethernet/RS485, goyan bayan http/snmp/ssh2/modbus
10. Onboard LCD nuni tare da sarrafa menu da kulawa na gida
-
30 Ports P34 Smart PDU
Bayanan Bayani na PDU:
1. Input ƙarfin lantarki: 3-phase 346-480 VAC
2. Shigarwa na yanzu: 3 x 250A
3. Wutar lantarki na fitarwa: 3-phase 346-480 VAC ko guda-lokaci 200 ~ 277 VAC
4. Outlet: 30 tashoshin jiragen ruwa na 6-pin PA45 Sockets da aka tsara a cikin sassa uku
5. Kowane tashar jiragen ruwa yana da 3P 30A UL489 Circuit Breaker
6. PDU ya dace don 3-phase T21 da S21 guda-lokaci
7. Mai saka idanu mai nisa na shigar da halin yanzu, ƙarfin lantarki, wutar lantarki, factor factor, KWH
8. Onboard LCD nuni tare da sarrafa menu
9. Ethernet / RS485 dubawa, goyon bayan HTTP / SNMP / SSH2 / MODBUS
10. Ciki mai hurawa fan tare da matsayi LED nuna alama
-
16 Tashar jiragen ruwa L7-20R Smart PDU
Bayanan Bayani na PDU:
1. Input ƙarfin lantarki: 3-phase 346-480 VAC
2. Shigarwa na yanzu: 3 x 200A
3. Wutar lantarki mai fitarwa: guda-lokaci 200 ~ 277 VAC
4. Kanti: 16 tashoshin jiragen ruwa na L7-20R Sockets
5. Kowane tashar jiragen ruwa yana da 1P 25A Circuit Breaker
6. Mai saka idanu mai nisa na shigar da halin yanzu, ƙarfin lantarki, wutar lantarki, factor factor, KWH
7. Onboard LCD nuni tare da sarrafa menu
8. Ethernet / RS485 dubawa, goyon bayan HTTP / SNMP / SSH2 / MODBUS
-
24 Tashar jiragen ruwa P34 Smart PDU
Bayanan Bayani na PDU:
1. Input ƙarfin lantarki: 3-phase 346-480 VAC
2. Shigarwa na yanzu: 3 x 200A
3. Wutar lantarki na fitarwa: 3-phase 346-480 VAC ko guda-lokaci 200 ~ 277 VAC
4. Outlet: 24 tashoshin jiragen ruwa na 6-pin PA45 Sockets da aka tsara a cikin sassa uku
5. Kowane 3P 25A Circuit Breaker yana sarrafa kwasfa 3
6. PDU ya dace don 3-phase T21 da S21 guda-lokaci
7. Kulawa mai nisa da sarrafa ON / KASHE kowane tashar jiragen ruwa
8. Mai saka idanu mai nisa na shigar da halin yanzu, ƙarfin lantarki, wutar lantarki, factor factor, KWH
9. Onboard LCD nuni tare da sarrafa menu
10. Ethernet / RS485 dubawa, goyon bayan HTTP / SNMP / SSH2 / MODBUS
11. Ciki fan tare da LED nuna alama
-
16 Tashar jiragen ruwa P34 Smart PDU
Bayanan Bayani na PDU:
1. Input ƙarfin lantarki: 3-phase 346-480 VAC
2. Shigarwa na yanzu: 3 x 300A
3. Wutar lantarki na fitarwa: 3-phase 346-480 VAC ko guda-lokaci 200 ~ 277 VAC
4. Outlet: 16 tashoshin jiragen ruwa na 6-pin PA45 Sockets da aka tsara a cikin sassa uku
5. Kowane tashar jiragen ruwa yana da 3P 25A Circuit Breaker
6. PDU ya dace don 3-phase T21 da S21 guda-lokaci
7. Kulawa mai nisa da sarrafa ON / KASHE kowane tashar jiragen ruwa
8. Mai saka idanu mai nisa na shigar da halin yanzu, ƙarfin lantarki, wutar lantarki, factor factor, KWH
9. Onboard LCD nuni tare da sarrafa menu
10. Ethernet / RS485 dubawa, goyon bayan HTTP / SNMP / SSH2 / MODBUS
11. Ciki fan tare da LED nuna alama